PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profileg
PlumbTec (NW) Ltd

@plumb_tec

Plumbing and Heating Engineers - Heat pump - Air Conditioning - MVHR - Fgas

ID:1364941527450066946

linkhttp://www.plumbtec.uk calendar_today25-02-2021 14:13:23

92 Tweets

93 Followers

116 Following

PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Taking a minute before I put up a window blind for the wife. Admiring the wind turbines over on Scout Moor. What a beautiful September afternoon

account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Shiny new Panasonic L series in the house. Can’t wait to have this piped up to see what it performs like compared to the previous generation. R290 outdoor with internal hydro box and 200L cylinder

Shiny new Panasonic L series in the house. Can’t wait to have this piped up to see what it performs like compared to the previous generation. R290 outdoor with internal hydro box and 200L cylinder #HeatPumps
account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

I really feel sorry for people who get ripped off by rouge installers. £25k for a Midea system is bad enough. But on top of that is seems like it wasn’t designed or installed correctly

account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Looks like Bury Council and Greater Manchester Combined Authority are advertising for the big boys. I’m all for raising awareness of heat pumps but why not direct people to local independent installers? The big boys have ECO schemes and huge marketing budgets. So disappointed with this approach

Looks like @BuryCouncil and @greatermcr are advertising for the big boys. I’m all for raising awareness of heat pumps but why not direct people to local independent installers? The big boys have ECO schemes and huge marketing budgets. So disappointed with this approach
account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

9KW Panasonic T-Cap unit with a 300L DHW cylinder and 3 piped 100L buffer. All for a 350m2 new build in Cheshire

9KW Panasonic T-Cap unit with a 300L DHW cylinder and 3 piped 100L buffer. All for a 350m2 new build in Cheshire
account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Just tried calling the BUS application helpline. Greeted with a recorded message to say they are closed. Lines only open until 12.30 on a Wednesday!! Is this really how Ofgem think they can clear the backlog of applications? I’m in disbelief

account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

One of two 16kw Refrigerant splits going into this 400 year old property. Major pipework routing issues but we can find solutions to any problem. Definitely not one for Octopus Energy

One of two 16kw Refrigerant splits going into this 400 year old property. Major pipework routing issues but we can find solutions to any problem. Definitely not one for @OctopusEnergy
account_circle
Department for Science, Innovation and Technology(@SciTechgovuk) 's Twitter Profile Photo

NEW: The Boiler Upgrade Scheme is now open to property owners in England and Wales.

Get £5,000 to help replace your oil or gas boiler with an efficient, low-carbon heat pump 🌡️

Find out more: gov.uk/government/new…

account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Here’s a twin Ideal ASHP installation we completed near the end of RHI. New kit to the market and from what I’ve seen they should do well

Here’s a twin Ideal ASHP installation we completed near the end of RHI. New kit to the market and from what I’ve seen they should do well
account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Over 900m of ground collector going in for this ground source install. Looking to have it up and running in the coming weeks in time for RHI

Over 900m of ground collector going in for this ground source install. Looking to have it up and running in the coming weeks in time for RHI
account_circle
PlumbTec (NW) Ltd(@plumb_tec) 's Twitter Profile Photo

Called out to a 15KW aroTHERM that wasn’t getting heat into the system durning this cold snap. Look at the condition of this coil. Advised the client about annual servicing. This system had been in around 5 years and by the look of it never serviced

Called out to a 15KW aroTHERM that wasn’t getting heat into the system durning this cold snap. Look at the condition of this coil. Advised the client about annual servicing. This system had been in around 5 years and by the look of it never serviced #DefrostCycle
account_circle